This box indicates if
the zone contains an open combustion unit. Extra ventilation air is surcharged
for such an open combustion unit. Examples of open combustions units are
geysers, boilers, gas stoves, or fireplaces which extract air for combustion
from the heated calculation zones. Only one combustion unit can be specified per
zone.
EPG
The type of
combustion unit within the heated calculation zone is indicated here. The
specific air volume flow required for this combustion unit, and a correction
factor for operation time are determined depending on the type of combustion
unit.
•Geyser without extract
•Bathroom geyser
•Gas water heater
•Boiler
•Open atmospheric heating, without extract
•Fireplace, natural exhaust, blocks fire type I
•Fireplace, natural exhaust, blocks fire type II
•Fireplace, blocks fire type II
•Fireplace
•Gas stove
•Oil stove
•Coal stove
•Stove, solid fuel other than coal
|
NEN 8088, Table 8 http://www.nen.nl/web/Normshop/Norm/NENENISO-77302005-en.htm |
EPG
The nominal load of
the combustion unit determines the air volume flow required for the combustion
unit. The minimum values for nominal load are applied in case the power is not
specified or the specified power is too low.
|
NEN 8088, Table 8 http://www.nen.nl/web/Normshop/Norm/NENENISO-77302005-en.htm |