The heat transfer
coefficient of the heat storage is determined flat rate by default, but may also
be specified in detail by presenting an own heat transfer coefficient in W/K.
This coefficient is used to determine the heat loss and heat storage. The heat
transfer coefficient is only asked for if the calculation method is performed in
detail and according to method B.
EPG
The location of the
storage tank is important as it is used to determine the heat loss.
§ Outside
The heat loss of the storage tank is determined
with the outside air as ambient temperature.
§ Unheated
space
The heat loss of the storage tank is determined with an ambient
temperature in between the heated space and the outside air.
§ Heated
space
The heat loss of the storage tank is determined with an ambient
temperature equal to the heated space.
[dm3] EPG
The total volume of the storage tank of the solar
energy system is specified here, expressed in dm3. The volume is used
to determine the reduction factor for the yield of solar energy in PVT-systems,
and to determine the correction factor for the efficiency of heat storage in
systems with integrated reheating.
[dm3] EPG
The volume of the storage tank which includes the
reheating is specified here, expressed in dm3. The volume is used to
determine the energy storage losses in systems with integrated
reheating.
[m²] EPG
This includes the net collector surface area of the
solar water heater (only for solar water heater).