HL BS EPG
This box
indicates whether a mechanical supply for the air handling system is present.
Checking this box affects the ventilation system type in the top of the Air
handling screen.
[Pieces] EPG
This number represents the number of ventilators
within the air handling unit. This input can only be specified in case the
Ventilation power is determined using the detailed method in the EPG
calculation. The ventilation power in the system also includes the ventilation
power on room level, as is the case with fan coils.
EPG
This is the nominal
power per fan in W. In case multiple fans have been defined, the nominal power
is multiplied by the number of fans. The ventilation power in the system also
includes the ventilation power at room level, as is the case with fan
coils.
HL BS EPG
This indicates
whether the heating of air caused by the supply fan should be taken into
account. The amount of heating should be specified in Kelvin.
•Vabi default the heating by the supply fan is taken as 1.5 K
•User defined the heating by the supply fan can be specified between 0 and 4 K
EPG
The regulation
(control) of the supply grilles can be specified in case no mechanical supply is
available, and consequently the supply air is extracted from outside. The supply
grilles partially determine the ventilation control type in the top of the
screen, which is used for the energy performance EPG calculation.
•No control
•Wind pressure driven flow Δp ≤ 1 Pa
•Wind pressure driven flow 1 Pa <Δp ≤ 5 Pa
•Wind pressure driven flow 5 Pa <Δp ≤ 10 Pa
•Time control without zoning
•CO2 control on indirect supply in each living room, without zoning
|
NEN 8088, Tables 2 and 5 |