Adjacency

The adjacency of the selected building part(s) can be edited using the checkbox in the table. If the adjacency of multiple constructions needs to be edited at once, you should use the button Change selection. A screen will appear in which the adjacency of the construction may be modified into another adjacency than the adjacency following from the geometry.  The option ‘According to geometry’ allows you to go back to the adjacencies which follow from the geometry. The adjacency can be modified into the following options:

Identical room
The temperature at the other side of the building part is assumed the same as inside the room.

Other building

One of the following building types is assumed at the other side of the building part:

§ Row dwelling,

§ Piled building,

§ Office or rental,

§ Local heating.

In addition, the ground properties of the other building should be specified. This includes the same components as in the template building requirements.

Unheated room

The type of unheated space can be chosen from the following selection:

§ Internal room,

§ Room ventilated with outside air,

§ Attic with uninsulated floor and insulated roof,

§ Attic with uninsulated floor and roof,

§ Room with single façade without door,

§ Room with single façade with door,

§ Room with two façades without door,

§ Room with two façades with door,

§ Room with three facades,

§ Room not according to Dutch Building Code.

Strongly ventilated room
EPG
A strongly ventilated room is assumed on the other side of the building part.

Crawl space

The average temperature in the crawl space on the other side of the building part is requested here. By default, the temperature is 12 °C. The outside temperature should be applied in case of well insulated floors (RC >= 4 (m² · K) / W) and in case of well ventilated crawl spaces.

isso.gif

BS

ISSO Publication 32 (2011), section 3.3

Crawl space temperature

http://www.issodigitaal.nl/?action=login&externalaction=linkmanager&id=docs/publicatie/32/3.html/3.3


Ground

The adjacency ground is applied here.

Water
The adjacency water is applied here.

User defined

The temperature on other side of the building part is specified here during day and night, and summer and winter.