1-11-2017
• For some generators it is possible to calculate with partial efficiency: boilers, heat pumps, compression chillers and absorption chillers. Therefore the input screen is changed;
• The settings of comfort charts are now saved as long as the project is not closed;
• The temperature control room can now be set for air handling units;
• The calculation engine is now a 64bit version;
• Heating and cooling coils without power are now calculated better;
• Air flows between rooms can be given in 2 decimals for m³/h;
• Input of air curves in air handling is optimised;
• Calculation of VAV systems is optimised;
• Calculation of multiple air handling units with adiabatic cooling is better;
• Calculation of faces with 0,001m² is optimised;
• DIS-loop message now happens less frequently.
• Calculation of results for buildings is improved;
• Result table input summary is added;
• More energy carriers are now calculated: external heat, external cold and oil:
o The input is extended;
o The output tables are optimised;
o The output charts are optimised;
• Export to excel is added to charts;
• Air flows between rooms can be given in 2 decimals for m³/h;
• Output of thermally active ceiling and heated ceiling is optimised;
• The field gross volume of building is improved.
• In result tables column room number and room name are now two columns;
• The variant screen is improved;
• Toolbar button ‘variant screen’ is added;
• With adding a variant, results are not copied;
• It is now possible to not save results in the project;
• The default value of “saving results” can be set;
• It is now possible to add decimal numbers in Performance Dashboard;
• The temperature control room input is improved (including undo/redo);
• Template “HVAC” can now have colours;
• Screen updating of property screens is improved;
• Sorting rooms on column name is optimised;
• Volume calculation of variants is optimised;
• Air handling crash in library is fixed;
• Undo / redo on custom values in property screens is improved;
• Undo / redo in variant screen is optimised;
• The screen Location is improved.
• It is now possible to import gbXML files;
• Default option is now “Select”
• Selection after BIM-import is optimised;
• Saving of images is improved;
• Rotation of building parts is improved;
• Deleting floors is improved;
• Placing the comfort point is optimised.
• The screen distribution domestic hot water is optimised;
• The output chart can now exported to Excel;
• Custom shading reduction factors are added;
• Chart colours are optimised;
• Custom values for domestic hot water is now possible;
• Water flow of cold storage can now filled in with 5 decimals.
• The output chart can now exported to Excel.
• Adding rooms to habitable spaces is improved.
• Plugins can now use the group “buildings”;
• It is now possible to show input in output tables of plugins.