1-4-2016
Service updates
A solution is added for a problem with big outputfiles in HVAC in Building Simulation Calculation;
A solution is added for working with multiple displays;
A solution is added for shading of glazing in the Building Simulation Calculation;
A solution is added for using multiple building in geometry;
A solution is added for activation of Elements;
A solution is added for 3D views in the output tables;
A solution is added for using radiant heating and cooling panels;
A solution is added for a problem in groups in Ventilation Check;
A solution is added for a new EPCheck setup;
A solution is added for a problem with faces with area 0 in Buidling Simulation Calculation;
A solution is added for the EPG calculation with some specials walls.
3.0 – Release Building Performance Platform
1-3-2015
• The calculation speed is much faster;
• The geometry calculation engine is much faster;
• The RTF-reports are more complete;
• It is possible to use a different time schedule for HVAC fo each room;
• There are more results available in the Technical and Performance Dashboard;
• A solution is added for some types of Heat Recovery;
• A solution is added for the calculation of some overheating calculation hours;
• A solution is added for the excel export of the daily output graphs;
• A solution is added for the mouse-over in the daily output graphs;
• The Energy Use, CO2-emission, Energy Costs and Primary Energy are now calculation including the energy use of domestic hot water, lifts, catering and electricity generation.
• Results are presented tables, bar- and pie graphs;
• It is possible to make a calculation Payback period;
• It is possible to calibrate a model according the International Performance Measurement and Verification Protocol (IPMVP)
• A dashboard to present the most important results in one screen with this split in this main groups: Energy, Environment, Financial, Installation and Productivity;
• Possible to show a variant in the screen;
• There are three views of the dashboard: Performance, Radar and Table;
• Each result is available in 3D;
• Each result can have a different weighting in the total score;
• For each result is it possible to set own standard and ambition values.
• Make user defined table views;
• Each column can be set in a 3D view;
• It is possible to export the tables to Excel.
• New module to check the ventilation flows to the building regulations in the Netherlands;
• Visualize ventilation flows in 3D and 2D.
• New module to check the reverberation in rooms to the building regulations in the Netherlands;
• Calculation conform NEN-EN 12354-6;
• Results per octave band in tables and graphs;
• Split on a face is now possible;
• Possible to draw a room within another room;
• Draw a line through multiple faces;
• A solution is added for stitching of rooms;
• DWG and DXF-files can be placed as a carpet in the drawing environment to act as a guide when drawing buildings directly in the software;
• A solution is added for the realistic view;
• A solution is added for drawing lines.
• It is possible to mirror building parts.
• A solution is added for a calculation with always closed blinds;
• The geometry calculation engine is much faster;
A solution is added for rounded walls.
• Results of the EPG visual in an pie graph;
• A solution is added for calculation of domestic hot water;
• Detailed shading: the geometry calculation engine is much faster.
• A solution is added for rounded walls.
• A solution is added for the undo and redo function.
A solution is added for the copy function in the central library.
2.2.1 – Service Update
19-8-2015
• A solution is added for a problem with the multiple use of air handling systems in Building Simulation.
• A solution is added for English translations.
• A solution is added for performance while editting templates.
• A solution is added for applying room templates for multiple rooms.
• A solution is added for a problem with the EPG-calculation in the Netherlands.
• A solution is added for opening an EPG-calculation in EPCheck.2.2.0 – Summer 2015 release
1-7-2015
• The building simulation calculation is improved and is compatible with more than three distrubution nets in one calculation.
• The building simulation calculation is improved and is compatible with more than one air handling systems in one calculation. The maximum of one time schedule per calculation is still there.
• The building simulation calculation is improved and is compatible with the use off unlimited emissive divices in one calculation. There is a maximum of two emmisive divices plus a variable air volume unit in one room.
• The building simulation calculation is now compatible with more than 10000 building parts per room.
• The classes of the ATG graphs are now conform ISSO publication 74 (2014).
• The control on ATG are now conform ISSO publication 74 (2014).
• It is now possible to fill the yield for local VRV and VRF systems.
• It is now possible to fill in a lower Ψ-value.
• The complete help functionality of Elements is now on the web.
• The Dutch URL for the help is: http://help.vabi.nl/elements/nl/index.html.
• The English URL for the help is: http://help.vabi.nl/elements/en/index.html.
• The help is now in a new interface.
• By selectiong a field in Elements and push the button F1, you will automatically be forwarded to the right paragraph in the help.
• There is a Vabi Elements API Development guide for companies who want to make plugins for Elements: http://help.vabi.nl/elements/api/index.html.
• The messages of the calculations are improved.
• The functions draw polygonal room and rectangular room are improved. It is now possible to fill automatically the space between a couple of rooms with a new room.
• The import of round walls is improved.
• The realistic view is improved.
• There is a solution added for a problem with the function “Apply on selection”.
• The definition for air distribution temperatures for the Heat Loss calculation is improved.
• There is a solution added for some refreshing problems in a couple of screens.
• A solution has been added for the out of balance message which appears incorrect.
• The reports of Building Simulation, Heat Loss and Cooling Load are improved.
• There are some solutions added for drawing problems in the geometry.
• A solution has been added for some computers who experienced problems with the geometry calculation.
• A solution has been added to improve the library.